121 assays found tagged with Arbor Assays

Arbor Assays DetectX® Cortisol

Quantitative determination of cortisol present in dried fecal extracts, saliva, urine, serum, plasma and tissue culture media samples. Data analysis is performed in accordance with Arbor Assays' DetectX Cortisol kit (K003-H1, K003-H1W, K003-H5, K003-H5W, K003-H, K003). All samples are corrected by the mean of the NSB group measurements. The standard data points are plotted (concentration vs. B/B0%) and a Four Parameter Logistic Fit is made through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied.

Arbor Assays DetectX® Corticosterone (RLU)

The DetectX® Corticosterone Immunoassay kit is designed to quantitatively measure Corticosterone present in extracted dried fecal samples, serum, plasma and tissue culture media samples. Data analysis is performed in accordance with Arbor Assays' DetectX Corticosterone kit K014-C1, K014-C5, K014-C, K014. Data should be measured with a colorimetric 96 well microplate reader measuring reading glow chemiluminescence. The measured Relative Light Units (RLU) are processed as follows: All samples are corrected by the mean of the NSB group measurements. The standard data points are plotted (concentration vs. B/B0%) and a Four Parameter Logistic Fit is made through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied.

Arbor Assays DetectX® Corticosterone (OD)

The DetectX® Corticosterone Immunoassay kit is designed to quantitatively measure Corticosterone present in extracted dried fecal samples, serum, plasma and tissue culture media samples. Data analysis is performed in accordance with Arbor Assays' DetectX Corticosterone kit K014-H1, K014-H5, K014-H, K014. Data should be measured with a colorimetric 96 well microplate reader measuring Optical Densities (OD) at 450nm. All samples are corrected by the mean of the NSB group measurements. The standard data points are plotted (concentration vs. B/B0%) and a Four Parameter Logistic Fit is made through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied.

Arbor Assays Acetylcholinesterase Fluorescent Activity kit

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' Acetylcholinesterase Fluorescent Activity kit (K015-F1, K015-F, K015). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. FLU) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays Atrial Natriuretic Peptide (ANP) EIA kit

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' Atrial Natriuretic Peptide (ANP) EIA kit (K026-H1, K026-H5, K026-H, K026). All samples are corrected by the mean of the NSB group measurements. The standard data points are plotted (concentration vs. %B/B0) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays BCA Protein Colorimetric Detection Kit High Range (Legacy)

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' BCA Protein Colorimetric Detection Kit High Range (K041-H1, K041-H, K041). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. OD) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays BCA Protein Colorimetric Detection Kit Low Range

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' BCA Protein Colorimetric Detection Kit Low Range (K041-H1, K041-H, K041). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. OD) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays Butyrylcholinesterase Fluorescent Activity kit

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' Butyrylcholinesterase Fluorescent Activity kit (K016-F1, K016-F, K016). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. FLU) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays Catalase Colorimetric Activity kit (Legacy)

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' Catalase Colorimetric Activity kit (K033-H1, K033-H, K033). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. OD) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Arbor Assays Catalase Fluorescent Activity kit

This data analysis calculates concentrations using a Four Parameter Logistic (4PL) curve fit in accordance with Arbor Assays' Catalase Fluorescent Activity kit (K033-F1, K033-F, K033). The average of the zero measurements is subtracted from each sample. The standard data points are plotted (concentration vs. FLU) on semi-log axes and a 4PL curve is fitted through these points. The concentrations of the unknown samples are determined from the fit and any specified dilution factors are applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.
<< First< Previous
Page 1 of 13 (121 assays)
Next >Last >>