65 assays found tagged with EIA
A competitive immunoassay for the quantitative determination of Corticosterone (also referred to as Kendall's Compound B and Reichstein Substance B) in biological fluids.
Linearized quantification of sample concentrations for enzyme immunoassay (EIA). This uses the linearized method which plots logit B/B0 versus log concentration using a linear fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme Immunoassay (EIA) for the quantitative determination of endogenous asymmetric dimethylarginine (ADMA) in serum or plasma.
Enzyme immunoassay (EIA) for the quantification of Prostaglandin E2 - Monoclonal. This method plots %B/B0 for the standards versus PGE2 concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of Leukotriene B4 (4PL). This method plots %B/B0 for the standards versus LTB4 concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of 8-Isoprostane. This method plots %B/B0 for the standards versus 8-isoprostane concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of Cyclic AMP - Acetylated (4PL). This method plots %B/B0 for the standards versus cAMP concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of Cyclic AMP - Non-Acetylated (4PL). This method plots %B/B0 for the standards versus cAMP concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of Cyclic GMP - Acetylated (4PL). This method plots %B/B0 for the standards versus cGMP concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.
Enzyme immunoassay (EIA) for the quantification of Cyclic GMP - Non-Acetylated (4PL). This method plots %B/B0 for the standards versus cGMP concentration using linear (y) and log (x) axes and performs a 4-parameter logistic fit. Sample positions with %B/B0 values greater than 80% or less than 20% are highlighted in yellow. These samples should be re-assayed as they generally fall out of the linear range of the standard curve.